Copper Shines in Radiant Heating
Edition #86: Winter 1998
![]() An array of copper tubing for under-floor radiant heating before pouring the concrete flooring. This installation in a Chicago area home was by Geegan Heating. |
|
Bob Geegan, a mechanical contractor who has been installing radiant heating for 30 years, reports that some of his very first installations are still as efficient and reliable as the day they began operating. He does not install any PEX, which he rates inferior to copper in several ways, such as much lower heat transfer and not having passed the test of time. Geegan also disputes the claim by advocates of PEX that it is easier to install than copper tubing and that the alkali in the concrete laid over the copper tubing corrodes it, which is contrary to scientific fact.
In the Chicago area, his 30-employee firm, Geegan Heating, installs some 150,000 feet of 5/8-inch OD annealed copper tubing each year to provide under-floor radiant heating, mostly in low-rise condos. Geegan also relies on the longevity of copper systems for outdoor installations to melt snow on sloping driveways (see illustration below), sidewalks and pedestrian areas.
Another expert, Tom Marvin, a veteran builder in Kirkland, Washington, a suburb of Seattle, insists that copper tubing is quite easy to install. He also reports that PEX costs more than copper tubing in his area. And, according to Marvin, some installations of PEX tubing have developed disastrous leaks.
![]() An array of copper tubing for melting snow prior to pouring a concrete driveway. This Chicago condominium installation was by Geegan Heating. |
In the Northwest, domestic water heaters can provide enough heat to operate under-floor radiant heating systems, says Marvin. In the Chicago area, which is, of course, much colder in winter than the Northwest, Geegan finds that a split system is an efficient means to provide overall comfort in condo projects. He installs gas-fired boilers to heat the water that runs through the tubing. The hot water from these boilers also supplies heat to a copper heat exchange coil in the air handler of each condo unit to provide forced hot air heating. The water is distributed to the tubing through copper manifolds. These are closed systems, which offer higher efficiency because the water exiting the under-floor tubing retains some heat on its return trip to the boiler.
Geegan obtains his copper tubing (C12200) from suppliers in the Chicago area.
Geegan Heating: 847/593-0123
Tom Marvin: 425/822-8267